Craftsman 390.262553 Instrukcja Właściciela

Przeglądaj online lub pobierz Instrukcja Właściciela dla Pompy wodne Craftsman 390.262553. Craftsman 390.262553 Owner`s manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
SEARS
OWNER'S
MANUAL
MODELNO.
390.262454
390.262553
390.262653
CAUTION:
Read and Follow
All Safely Rulesand
Operating Instructions
BeforeFirstUseof
ThisProduct.
Save ThisManual For
Future Reference.
MODEL NOS.
390.262454
390.262553
MODEL NO. 390.262653
I:RI:IF'rSMg N°
HYDROGLASS ®
HIGH PRESSURE
SPRINKLER PUMP
Safety Instructions
Installation
Electrical
•Maintenance
Repair Pa_s
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A. Form No. F642-9908 (Rev. 8/18/03)
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - I:RI:IF'rSMg N°

SEARSOWNER'SMANUALMODELNO.390.262454390.262553390.262653CAUTION:Read and FollowAll Safely RulesandOperating InstructionsBeforeFirstUseofThisProdu

Strona 2 - INTRODUCTION

TROUBLESHOOTING CHARTSYMPTOM CORRECTIVE ACTIONMotor willnot run f. Be sureswitchis onPOSSIBLE CAUSE(S)1. Disconnectswitch is off2. Fuse is blown3. Sta

Strona 3 - INSTALLATION

REPAIR PARTS20348A11A1.SearsProductService,1-800-366-7278 12" , ...310yI F>mr,'_ 10KeyNo11A1BIC23456788A9101111A121314161716192021Motor

Strona 4 - Pump/Piping Installation

S£ A[RSOWNER'SMANUALModel No.390.262454390.262553390.262653The model number ofyour Sprinkler Pumpwillbe found on a plateattached to the side ofth

Strona 5 - ELECTRICAL

CONTENTSINTRODUCTION/XVARRANTY ... 2SAFETY ...

Strona 6 - ELECTRICAL (Continued)

PREPARATIONBASIC TOOLS AND MATERIALS NEEDEDPipe Wrenches ScrewdriverHacksaw Check ValveAdjustable Wrench Teflon TapeKnifeINSTALLATION (Continued)Sucti

Strona 7 - OPERATION

INSTALLATION (Continued)2. To aid priming on driven point installations, install a linecheck valve as shown in Figure 2. Be sure check valveflow arrow

Strona 8 - MAINTENANCE

ELECTRICALConnection diagram for dual voltage, single-phase motors.Your dual-voltage motor's terminal board (under the motorend cover) will match

Strona 9 - MAINTENANCE (Continued)

ELECTRICAL (Continued)3. Disconnect power before servicing motor or pump. If thedisconnect switch is out of sight of pump, lock it openand tag it to p

Strona 10 - TROUBLESHOOTING CHART

OPERATIONPRIMING THE PUMPNOTICE: 'Priming' refers to the pump expelling all air in thesystem and beginning to move water from its source out

Strona 11 - REPAIR PARTS

MAINTENANCEPump and piping need not be disconnected to repair or re-place motor or seal (see Figure 12). If motor is replaced, re-place the shaft seal

Strona 12 - CRgFTSMRN°

MAINTENANCE (Continued)4. Place pump body half face down on flat surface and tapout stationary half of seal (see Figure 16).9. Hold motor shaft with 7